Council planning record

Variation of condition no 2 (Approved plans) and 3 (Arboricultural Method Statement and Tree Protection Plan) on application ref P23/V1663/HH - to amend the following: -The existing rear garage brick wall and window are now to be retained and reused as part of the extension facade. As such the south-east extension width is marginally extended each side (by circa 275mm) from that previously consented to match the existing main house gable wall width. Furthermore, the eaves and ridge height are adjusted to match the existing house as well for continuity. - The associated side porch design is adapted to suit the revised eaves line. - Addition of 2x conservation rooflights to the east elevation of the south-east extension. - Amended fenestration to the south elevation of the south-east extension. - The proposed dormer to the south-east corner of the existing house is enlarged to facilitate adequate first floor bathroom head height. - Provision of an additional west window and new southern external door to the ground floor study of the north-west extension. - Minor door and window location adjustments to suit amended internal layout to front elevation of north-west extension. and to remove Condition 3, as Arboricultural Method Statement has been provided to discharge the condition. (One and half-storey extensions to the northwest and south elevations following partial demolition of the existing garage).

Appleford House, Church Street, Appleford, Abingdon, OX14 4PB

Decision MadeReference: P26/V0577/S73Vale of White Horse District Council

Application location

Appleford House, Church Street, Appleford, Abingdon, OX14 4PB

This record has no verified map location.

Application summary

Status
Decision Made
Application type
Not published
Received
5 Mar 2026
Validated
Not published
Determination deadline
Not published
Local authority
Vale of White Horse District Council

Application overview

Variation of condition no 2 (Approved plans) and 3 (Arboricultural Method Statement and Tree Protection Plan) on application ref P23/V1663/HH - to amend the following: -The existing rear garage brick wall and window are now to be retained and reused as part of the extension facade. As such the south-east extension width is marginally extended each side (by circa 275mm) from that previously consented to match the existing main house gable wall width. Furthermore, the eaves and ridge height are adjusted to match the existing house as well for continuity. - The associated side porch design is adapted to suit the revised eaves line. - Addition of 2x conservation rooflights to the east elevation of the south-east extension. - Amended fenestration to the south elevation of the south-east extension. - The proposed dormer to the south-east corner of the existing house is enlarged to facilitate adequate first floor bathroom head height. - Provision of an additional west window and new southern external door to the ground floor study of the north-west extension. - Minor door and window location adjustments to suit amended internal layout to front elevation of north-west extension. and to remove Condition 3, as Arboricultural Method Statement has been provided to discharge the condition. (One and half-storey extensions to the northwest and south elevations following partial demolition of the existing garage).

Proposal details

Reference
P26/V0577/S73
Agent
WWA Studios

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents 33 of 33

DocumentPublishedAction
Application FormApplication FormNot publishedView
Las 690 04 Landscape ProposalsAmended PlanNot publishedView
1252-WWA-00-00-DR-A-0127-P14 - Proposed Ground Floor Plan (S73)General PlanNot publishedView
955-WWA-00-XX-DR-A-0003-P09 - Proposed Block PlanGeneral PlanNot publishedView
1252-WWA-00-XX-DR-A-0201-P11 - Proposed Elevations 01 (S73)General PlanNot publishedView
1252-WWA-00-00-DR-A-0128-P13 - Proposed First Floor Plan (S73)General PlanNot publishedView
1252-WWA-00-XX-DR-A-0202-P11 - Proposed Elevations 02 (S73)General PlanNot publishedView
1252-WWA-00-00-DR-A-0129-P08 - Proposed Roof Plan (S73)General PlanNot publishedView
1252-WWA-00-00-DR-A-0006-P02 - Proposed Site Plan (S73)General PlanNot publishedView
Arboricultural Method StatementSupporting documentationNot publishedView
Cover Letter Rev CSupporting documentationNot publishedView
2026-04-01 WebComment 1: FOR - Forestry Officer (South and Vale)Consultation Response - InternalNot publishedView
Forestry ResponseConsultation Response - InternalNot publishedView
Customer Letter: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
SSE Networks Plant Affected Letter: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
National Gas Transmission 40923814: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
2026-03-24 Linesearch Email 2: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
SSEN 40923814: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Map key: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
2026-03-24 Linesearch Email 3: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
SSEN Guide to Interpreting: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Watch it SSEN Dist: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Valve safety advice: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Know what's below: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
40923814 SGN: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
2026-03-25 WebComment 1: ZD1 - County Archaeologist (VWHDC)Consultation Response - ExternalNot publishedView
Dig Safely Measures to avoid injury and damage to gas pipes: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
40923814 Gigaclear Ltd: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
2026-03-24 Linesearch Email 4: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
2026-03-24 Linesearch Email 1: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Gigaclear Ltd Plant Affected Letter: SGN - SGN Plant Protection TeamConsultation Response - ExternalNot publishedView
Decision Notice_S&V PDFDecision NoticeNot publishedView
DM Officer Report FinalOfficer ReportNot publishedView

Documents open on the council website. Browse council documents if a link has changed.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Application Received Date

    Published milestoneCouncil source
  2. Issue Date

    Published milestoneCouncil source

Decision & conditions

Planning Permission is Granted
Decision Notice_S&V PDF

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.