ApprovedCouncil status: Listed Build - Prop Lawful Dev Granted

We wish to remove the existing (and non-functional/defunct) electric boiler (assuming it was installed in the 190s when the coach house was converted) and to install a Viessmann Vitotron 24Kw wall hung electric boiler. This will include installing any necessary copper pipework and fittings to connect the new boiler to our existing heating pipework, a boiler filter, suitable cleanser and inhibitor, and a new digital heating controller. The boiler is currently located on the ground floor, under the stairs, and we will keep it in this location. In the attic store room, we will remove the dated vented hot water cylinder and cold water tanks (plus all redundant items). We will install a new Telford Tempest 300 litre twin immersion direct hot water cylinder, 2 x 100-gallon coffin cold water break tanks and a DAB Esybox single booster hot water circulation pump (plus all necessary copper pipe work and fittings). In slower time, we will also replace all existing radiators and radiator valves (including the night storage ones on the top floor); all these look to have been installed in the 1980s) with more traditional-looking column radiators.

2 The Coach House Compton Verney Warwick CV35 9HJ

Stratford-on-Avon District CouncilReference 25/01820/LBPCertificate Lawful works to Listed Build

Last published check: 29 Oct 2026, 18:38. Check the council record for more recent changes.

Status and dates

Last published check: 29 Oct 2026, 18:38 (UK)

  1. DoneReceived29 Jul 2025
  2. DoneValidated29 Jul 2025
  3. Not publishedConsultationNo date on council record
  4. Not publishedTarget decision dateNo date on council record
  5. DecidedListed Build - Prop Lawful Dev Granted28 Aug 2025

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (4)
  1. applicationReceivedDate

    Published milestoneCouncil source
  2. applicationValidDate

    Published milestoneCouncil source
  3. dateDecisionIssued

    Published milestoneCouncil source
  4. targetDeterminationDate

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Certificate Lawful works to Listed Build
Ward
Wellesbourne East & Rural
Parish
Compton Verney
Documents
4 published

Proposal

We wish to remove the existing (and non-functional/defunct) electric boiler (assuming it was installed in the 190s when the coach house was converted) and to install a Viessmann Vitotron 24Kw wall hung electric boiler. This will include installing any necessary copper pipework and fittings to connect the new boiler to our existing heating pipework, a boiler filter, suitable cleanser and inhibitor, and a new digital heating controller. The boiler is currently located on the ground floor, under the stairs, and we will keep it in this location. In the attic store room, we will remove the dated vented hot water cylinder and cold water tanks (plus all redundant items). We will install a new Telford Tempest 300 litre twin immersion direct hot water cylinder, 2 x 100-gallon coffin cold water break tanks and a DAB Esybox single booster hot water circulation pump (plus all necessary copper pipe work and fittings). In slower time, we will also replace all existing radiators and radiator valves (including the night storage ones on the top floor); all these look to have been installed in the 1980s) with more traditional-looking column radiators.

Reference
25/01820/LBP
Ward
Wellesbourne East & Rural
Parish
Compton Verney
Agent
Ms Alison Wenham

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • Application FormCouncil document29 Jul 2025View
  • Delegated ReportCouncil document28 Aug 2025View
  • Decision LetterCouncil document28 Aug 2025View
  • Location PlanCouncil document29 Jul 2025View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Listed Build - Prop Lawful Dev Granted
Decision Letter
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Related records could not be loaded.

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.