RefusedCouncil status: Listed Build - Prop Lawful Dev Refused

The proposed works are 1) installation of a battery storage system 2) installation of multi split heating / cooling system to the kitchen and dining room Battery storage It is proposed to install a floor mounted battery storage system within the garage, the batteries will be located on an external wall beneath the existing wall mounted solar inverter. Each battery capacity is 13.5 kwh and each battery measures 1,099 x 609 x 193 mm in size. The batteries will be capable of be charged from the existing solar PV array and from overnight off peak electricity from the grid. It is proposed to install up to 3 batteries. Multi split system installation The multi split heating system comprises 3 main components a) 2 x wall mounted venting units b) 1 x wall mounted compressor unit. It is proposed to wall mount 1 venting unit at high level in each of the dining room extension and the kitchen. The compressor unit is to be mounted low level on the external wall of the dining room. Black pipework will run along the external wall at low level and enter the rear lobby near floor level and run vertically in the corner where it will be discreetly boxed in. There will not be any visible pipework in the kitchen or dining room because the vent units connections are at the rear. The compressor is 804 x 298 x 252 mm in size.

The Old Vicarage 13 High Street Bidford-on-Avon Alcester B50 4BQ

Stratford-on-Avon District CouncilReference 24/01824/LBPCertificate Lawful works to Listed Build

Last published check: 1 Nov 2026, 18:38. Check the council record for more recent changes.

Status and dates

Last published check: 1 Nov 2026, 18:38 (UK)

  1. DoneReceived22 Jul 2024
  2. DoneValidated30 Aug 2024
  3. Not publishedConsultationNo date on council record
  4. Not publishedTarget decision dateNo date on council record
  5. DecidedListed Build - Prop Lawful Dev Refused4 Oct 2024

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (4)
  1. applicationReceivedDate

    Published milestoneCouncil source
  2. applicationValidDate

    Published milestoneCouncil source
  3. dateDecisionIssued

    Published milestoneCouncil source
  4. targetDeterminationDate

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Certificate Lawful works to Listed Build
Ward
Bidford East
Parish
Bidford-on-Avon
Documents
12 published

Proposal

The proposed works are 1) installation of a battery storage system 2) installation of multi split heating / cooling system to the kitchen and dining room Battery storage It is proposed to install a floor mounted battery storage system within the garage, the batteries will be located on an external wall beneath the existing wall mounted solar inverter. Each battery capacity is 13.5 kwh and each battery measures 1,099 x 609 x 193 mm in size. The batteries will be capable of be charged from the existing solar PV array and from overnight off peak electricity from the grid. It is proposed to install up to 3 batteries. Multi split system installation The multi split heating system comprises 3 main components a) 2 x wall mounted venting units b) 1 x wall mounted compressor unit. It is proposed to wall mount 1 venting unit at high level in each of the dining room extension and the kitchen. The compressor unit is to be mounted low level on the external wall of the dining room. Black pipework will run along the external wall at low level and enter the rear lobby near floor level and run vertically in the corner where it will be discreetly boxed in. There will not be any visible pipework in the kitchen or dining room because the vent units connections are at the rear. The compressor is 804 x 298 x 252 mm in size.

Reference
24/01824/LBP
Ward
Bidford East
Parish
Bidford-on-Avon

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • Existing and Proposed ElevationsCouncil document3 Sept 2024View
  • LocationPlanCouncil document11 Sept 2024View
  • Additional infoCouncil document8 Nov 2024View
  • Additional infoCouncil document8 Nov 2024View
  • ApplicationFormRedactedCouncil document20 Dec 2024View
  • Powerwall-3-DatasheetCouncil document20 Dec 2024View
  • Daikin Multisplit detailsCouncil document20 Dec 2024View
  • WCC Ecology 23.09.2024Council document8 Nov 2024View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Listed Build - Prop Lawful Dev Refused
Decision Letter
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Related records could not be loaded.

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.