ApprovedCouncil status: Decision Made

Details of condition 4 (Fixed Plant & Equipment) of R24/0257. (Full planning application for the erection of a Vehicle Maintenance Unit (VMU), as an ancillary development within the yard area of the Unit 1 building (B8 use) at Padge Hall Farm, with associated yard, drainage and infrastructure works.)

LAND AT PADGE HALL FARM, WATLING STREET, BURBAGE

Rugby Borough CouncilReference R26/0289Conditions

Last published check: 3 Oct 2026, 23:09. Check the council record for more recent changes.

Status and dates

Last published check: 3 Oct 2026, 23:09 (UK)

  1. DoneReceived19 Mar 2026
  2. DoneValidated24 Mar 2026
  3. ClosedConsultationEnded 16 Apr 2026
  4. Date set by councilTarget decision date14 May 2026
  5. DecidedApproval27 Apr 2026

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (12)
  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Registration date

    Published milestoneCouncil source
  4. Press notice start date

    Published milestoneCouncil source
  5. Valid date

    Published milestoneCouncil source
  6. Consultation expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  7. Publicity end date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  8. Statutory expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  9. Dispatch date

    Published milestoneCouncil source
  10. Decision date

    Published milestoneCouncil source
  11. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  12. Decision expiry date

    Published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Conditions
Ward
Wolvey & Shilton
Parish
Stretton Baskerville
Documents
15 published

Proposal

Details of condition 4 (Fixed Plant & Equipment) of R24/0257. (Full planning application for the erection of a Vehicle Maintenance Unit (VMU), as an ancillary development within the yard area of the Unit 1 building (B8 use) at Padge Hall Farm, with associated yard, drainage and infrastructure works.)

Reference
R26/0289
Alternative references
PP-14793800
Ward
Wolvey & Shilton
Parish
Stretton Baskerville
Agent
Chris Gardner
UPRN
10094753037

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView
  • Condition information/Plans R'cd 19.03.2026Condition Info / PlanNot publishedView

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Approval
Discharge of conditions letter
Planning conditions
  1. 4 BREEAM Pol 05 External Plant Noise Impact Assessment - OP-C759 – AC - 2v1 Hinkley Distribution Centre Fixed Plant Maintenance Specification - Space Engineering Services Air Handling Unit Technical Specification - TIGFO-SBS-XX-ZZ-TS-M-9100-P02 Heat Recovery Unit Technical Specification - TIGFO-SBS-XX-ZZ-TS-M-9101-P02 Fan Coil Units Technical Specification - TIGFO-SBS-XX-ZZ-TS-M-9103-P02 Extract Fans technical Specification - TIGFO-SBS-XX-ZZ-TS-M-9102-P02 Goods In Air Source Heat Pumps Technical Specification - TIGFO-SBS-XX-ZZ-TS-M9104-P02 Mechanical Plant Schematic VMU - TIGFO-SBS-53-VMZZ-G-M-530510-P01 Heating & Cooling VMU Building Ground Floor - TIGFO-SBS-56-VMG1-D-M-560500-P01 Heating & Coolin VMU Building First Floor - TIGFO-SBS-56-VML1-D-M-560501-P01 Ventilation Services VMU Building Ground Floor - TIGFO-SBS-57-VMG1-D-M-570500-P01 Ventilation Services VMU Building First Floor - TIGFO-SBS-57-VML1-D-M-570501-P01
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.