Council planning record

Discharge of conditions C3 (glazing scheme) and C4 (ventilation scheme) pursuant to planning permission 25/00108/FUL

36 36A And 36B Cowgate Peterborough PE1 1NA

DeterminedReference: 26/002137/DISCHGPeterborough City Council

Last published check: 2 Oct 2026, 09:06. Check the council record for more recent changes.

Application location

36 36A And 36B Cowgate Peterborough PE1 1NA

This record has no verified map location.

Application summary

Status
Determined
Application type
Compliance with Planning Condition(s)
Received
25 Mar 2026
Validated
Not published
Determination deadline
16 Jun 2026
Local authority
Peterborough City Council

Application overview

Discharge of conditions C3 (glazing scheme) and C4 (ventilation scheme) pursuant to planning permission 25/00108/FUL

Proposal details

Reference
26/002137/DISCHG
Alternative references
PP-14808711
Development type
Discharge of Condition(s)
Ward
Central
Agent
Hartley
UPRN
10096481939

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents 17 of 17

DocumentPublishedAction
Application Form - RedactedDCAPFORM25 Mar 2026View
Accompanying Note for Conditions Discharge ResubmissionDCSUPDOC25 Mar 2026View
Existing and Proposed Elevation Plan - BB36 2EDCPLANS25 Mar 2026View
Proposed Floor Plans - BB36CD 1ADCPLANS25 Mar 2026View
Glazing SpecificationDCSUPDOC25 Mar 2026View
MVHR UNITDCSUPDOC25 Mar 2026View
TM59 ReportDCSUPDOC25 Mar 2026View
Copy of Decision 25/00108/FULDCPRDEC1 Apr 2026View
Comments - PollutionDCCONWEB14 May 2026View
Revised - MVHR Noise ChartsDCSUPDOC28 May 2026View
Revised - Clarification on mitigation for flatsDCSUPDOC28 May 2026View
Revised - Addendum to Noise Impact AssessmentDCSUPDOC28 May 2026View
Revised - Noise Impact AssessmentDCSUPDOC28 May 2026View
Revised - Applicant response to Env Health CommentsDCSUPDOC28 May 2026View
Revised: Proposed Floor Layout with MVHRDCPLANS1 Jun 2026View
Revised - Addendum to Noise AssessmentDCSUPDOC1 Jun 2026View
Decision -17/06/2025DCDEC17 Jun 2026View

Documents open on the council website. Browse council documents if a link has changed.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Registration date

    Published milestoneCouncil source
  4. Consultation expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  5. Statutory expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  6. Dispatch date

    Published milestoneCouncil source
  7. Decision date

    Published milestoneCouncil source
  8. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  9. Extension date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  10. Decision expiry date

    Published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source

Decision & conditions

Determined
Copy of Decision 25/00108/FUL Decision -17/06/2025
Planning conditions
  1. C3: Prior to installation, occupation and use a glazing scheme shall be submitted to and approved in writing by the Local Planning Authority. Where overheating is an issue, the scheme shall be developed in accordance with the Approved Doc O and where appropriate the Acoustic Ventilation and Overheating Residential Design Guide. Thereafter the development shall be implemented in accordance with the approved details, prior to the occupation of any unit to which it relates and shall thereafter be retained and maintained as such in perpetuity. Reason: To safeguard the future occupier amenity of the residential flats, in accordance with Policy LP17 of the Peterborough Local Plan (2019) and the National Planning Policy Framework (2024). Documentation submitted in support of C3: - Noise Impact Assessment (Ref. EV2447-01-B). - Addendum to Noise Impact Assessment. MVHR: Noise Control (Ref. EV2447-03-B). - MVHR Noise Charts - Email from Will Hughes to Planning Agent (Received: 28.05.26). - TM59 Overheating Report (Ref. 114846 Rev A). - MVHR Range Sentinel Specificaiton. - Glazing Specification (Calumen). - Accompanying Note (Received 25.03.26). Assessment: Having reviewed the submitted documentation, the Evolved Acoustics report ref: EV2447-01-B stated that the minimum sound insulation required for the glazing is 32dB Rw+Ctr. The proposed Calumen glazing states that sound reduction index is 36dB RW+Ctr, and therefore meets the requirement. The updated information confirms only Flat 5 requires a Solar Control Product or 1 meter of shading, these details are now included on the updated plans. The glazing and solar control shall be installed in accordance with approved plans. All other matters are acceptable. As such, the detail submitted is acceptable. Conclusion: The details submitted relating to condition 3 are acceptable to the Local Planning Authority and comply with the submission requirements of the condition. Condition 3 is hereby discharged.
  2. C4: Prior to installation occupation and use, a scheme which specifies the provisions for alternative ventilation of the development shall be submitted to and approved in writing by the local planning authority. Where appropriate the scheme shall comply with Approved Document F, Approved Doc O, and the Acoustic Ventilation and Overheating Residential Design Guide for design and acoustic specification purposes. Thereafter the development shall be implemented in accordance with the approved details, prior to the occupation of any unit to which it relates and shall thereafter be retained and maintained as such in perpetuity. Reason: To safeguard the future occupier amenity of the residential flats, in accordance with Policy LP17 of the Peterborough Local Plan (2019) and the National Planning Policy Framework (2024). Documentation submitted in support of C4: - Noise Impact Assessment (Ref. EV2447-01-B). - Addendum to Noise Impact Assessment. MVHR: Noise Control (Ref. EV2447-03-B). - MVHR Noise Charts - Email from Will Hughes to Planning Agent (Received: 28.05.26). - TM59 Overheating Report (Ref. 114846 Rev A). - MVHR Range Sentinel Specificaiton. - Glazing Specification (Calumen). - Accompanying Note (Received 25.03.26). Assessment: Having reviewed the submitted documentation, the Local Planning Authority accept the recommendations. The applicant has confirmed the ventilation system is the Vent Axia Sentinel Kinetic Plus B system. The ventilation shall be installed in accordance with the approved documents, including any acoustic mitigation to control break- in and self-made noise to acceptable levels. All other matters are acceptable. As such, the detail submitted is acceptable. Conclusion: The details submitted relating to condition 4 are acceptable to the Local Planning Authority and comply with the submission requirements of the condition. Condition 4 is hereby discharged.
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.