Council planning record

Discharge of conditions C3 (material finish), C4 (cycle shelter) and C6 (ventilation) of planning permission 23/01024/FUL

8 - 12 Priestgate Peterborough PE1 1JA

DeterminedReference: 26/00018/DISCHGPeterborough City Council

Last published check: 3 Oct 2026, 23:53. Check the council record for more recent changes.

Application location

8 - 12 Priestgate Peterborough PE1 1JA

This record has no verified map location.

Application summary

Status
Determined
Application type
Compliance with Planning Condition(s)
Received
6 Jan 2026
Validated
Not published
Determination deadline
3 Mar 2026
Local authority
Peterborough City Council

Application overview

Discharge of conditions C3 (material finish), C4 (cycle shelter) and C6 (ventilation) of planning permission 23/01024/FUL

Proposal details

Reference
26/00018/DISCHG
Alternative references
PP-14600640
Development type
Discharge of Condition(s)
Ward
Central
Parish
Peterborough
Agent
Mr Leon Delegate
UPRN
100090215693

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents 15 of 15

DocumentPublishedAction
Application Supporting Document: MVHR.Priestgate.Design Report.14.10.25DCSUPDOC6 Jan 2026View
Plans: 2820_AL0210_D04 - Proposed Site PlanDCPLANS6 Jan 2026View
Application Form: ApplicationDCAPFORM6 Jan 2026View
Representation from Consultee (Web): Conservation officer commentsDCCONWEB30 Jan 2026View
Representation from Consultee (Web): Pollution Control - commentsDCCONWEB4 Feb 2026View
DecisionDCDEC11 Feb 2026View
Application Supporting Document: TM59 Thermal Comfort Report - 8-12 Priestgate (3)DCSUPDOC6 Jan 2026View
Plans: JMA-2768-M - Ventilation Services RevB-Vent. First Fl.DCPLANS6 Jan 2026View
Representation from Consultee (Web): Local Highway Authority - CommentsDCCONWEB30 Jan 2026View
Plans: JMA-2768-M - Ventilation Services RevB-Vent. Second Fl.DCPLANS6 Jan 2026View
Application Supporting Document: TSO-20CG-iSR - Cool Grey 20DCSUPDOC6 Jan 2026View
Plans: JMA-2768-M - Ventilation Services RevB-Vent. Ground Fl.DCPLANS6 Jan 2026View
Previous/Parent decision notice: - Parent decision notice (Ref: 23/01024/FUL)DCPRDEC17 Apr 2024View
Plans: JMA-2768-M - Ventilation Services RevB-VENT AXIA DETAILS A3DCPLANS6 Jan 2026View
Plans: 2820_AL0230_D02_Bin Cycle StoreDCPLANS6 Jan 2026View

Documents open on the council website. Browse council documents if a link has changed.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Received date

    Published milestoneCouncil source
  2. Registration date

    Published milestoneCouncil source
  3. Dispatch date

    Published milestoneCouncil source
  4. Decision date

    Published milestoneCouncil source
  5. Consultation expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  6. Statutory expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  7. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  8. Application date

    Published milestoneCouncil source

Decision & conditions

Determined
Decision Previous/Parent decision notice: - Parent decision notice (Ref: 23/01024/FUL)
Planning conditions
  1. C3: Prior to the installation of the gates as shown on drawing number AL0210 Revision P04, details of the gate/s including material finish and colour shall be submitted to and agreed in writing by the Local Planning Authority. Thereafter the scheme shall be carried out in accordance with the approved details. Reason: For the Local Planning Authority to ensure a satisfactory external appearance, in accordance with Policies LP16 and LP19 of the Peterborough Local Plan (2019). Plans & documents submitted in support of the discharge of C3: - Proposed Site Plan (Drawing Number: AL0210 Rev D04). Assessment: Having reviewed the submitted documentation, the Local Planning Authority take the view that the submitted information is deemed to be acceptable. The existing gate is to be utilised, however will be repositioned to the adjacent wall. There is no objection to this. The gate is to be re-painted Blue (RAL 5017) which would ensure a satisfactory external appearance for the site and immediate surroundings. The proposal is considered to be acceptable to the Local Planning Authority. The requirements of C3 have been met. Conclusion: The details submitted relating to condition 3 are deemed acceptable to the Local Planning Authority and comply with the submission requirements of the condition. Condition 3 is hereby discharged, subject to implementation in accordance with the approved details.
  2. C4: Prior to the first commencement of use hereby permitted, details of an enclosed and secure cycle shelter to accommodate cycles shall be submitted and agreed in writing with the Local Planning Authority. This area shall thereafter be retained for the purposes of cycle parking in connection with the development in perpetuity. Reason: In the interests of highway safety and to encourage travel by sustainable modes, in accordance with Policy LP13 of the Peterborough Local Plan (2019). Plans & documents submitted in support of the discharge of C4: - Proposed Site Plan (Drawing Number: AL0210 Rev D04). - Proposed Bin and Cycle Store (Drawing Number: AL0230 Rev D02). Assessment: Having reviewed the submitted documentation, the Local Planning Authority take the view that the submitted information is deemed to be acceptable. The shelter is considered to meet the approach laid out in the approved permission. The design and storage capacity are acceptable and are in accordance with the parking standards for the site (16 max cycle spaces). The City Council's Conservation Officer and Local Highways Authority have no objection. The proposal is considered to be acceptable to the Local Planning Authority. The requirements of C4 have been met. Conclusion: The details submitted relating to condition 4 are deemed acceptable to the Local Planning Authority and comply with the submission requirements of the condition. Condition 4 is hereby discharged, subject to implementation in accordance with the approved details.
  3. C6: Prior to the first occupation and use of the development hereby permitted, a scheme which specifies the provisions for alternative ventilation of the development shall be submitted to and approved in writing by the Local Planning Authority. The scheme shall comply with Approved Document F, and the Acoustic Ventilation and Overheating Residential Design Guide for design and acoustic specification purposes. Thereafter the development shall be implemented in accordance with the approved details, prior to the occupation of any unit to which it relates and shall thereafter be retained and maintained as such in perpetuity. Reason: In the interest of future occupier amenity in accordance with Policy LP17 of the Peterborough Local Plan (2019). Plans & documents submitted in support of the discharge of C6: - Ventilation Ground FL. Flats (Drawing Number: 2768-JMA-M008 Rev B). - Ventilation First FL. Flats (Drawing Number: 2768-JMA-M009 Rev B). - Ventilation Second FL. Flats (Drawing Number: 2768-JMA-M010 Rev B). - Ventilation Details Sheets (Drawing Number: 2768-JMA-M012 Rev B). - Opalux Trade Solar Control Film: Lower Mirror - Cool Grey 20 - Internal (Received: 06.01.2026). - TM59 -Analysis of Thermal Comfort (Dated: 10.10.2025). - Mechanical Services Report for the Installation of Mechanical Ventilation (Received: 06.01.2026). Assessment: Having reviewed the submitted documentation, the Local Planning Authority take the view that the submitted information is deemed to be acceptable. The proposed ventilation scheme is accepted for use in the development. Future occupiers would not be subject to any impacts from overheating and adverse noise. The scheme shall comply with Approved Document F, and the Acoustic Ventilation and Overheating Residential Design Guide for design and acoustic specification purposes and be maintained as such in perpetuity. The City Council's Environmental Health Officer has no objection. The proposal is considered to be acceptable to the Local Planning Authority. The requirements of C6 have been met. Conclusion: The details submitted relating to condition 6 are deemed acceptable to the Local Planning Authority and comply with the submission requirements of the condition. Condition 6 is hereby discharged, subject to implementation in accordance with the approved details.
Related records

No related records were published in this section.

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.