Council planning record

Discharge of condition C15 (fire hydrants) pursuant to outline permission 19/01244/OUT

Gloucester Centre Morpeth Close Orton Longueville Peterborough

DeterminedReference: 25/01649/DISCHGPeterborough City Council

Last published check: 3 Oct 2026, 20:00. Check the council record for more recent changes.

Application location

Gloucester Centre Morpeth Close Orton Longueville Peterborough

This record has no verified map location.

Application summary

Status
Determined
Application type
Compliance with Planning Condition(s)
Received
23 Dec 2025
Validated
Not published
Determination deadline
13 Mar 2026
Local authority
Peterborough City Council

Application overview

Discharge of condition C15 (fire hydrants) pursuant to outline permission 19/01244/OUT

Proposal details

Reference
25/01649/DISCHG
Alternative references
PP-14586535
Development type
Discharge of Condition(s)
Ward
Hargate & Hempsted
Parish
Orton Longueville CP
UPRN
100091524097

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents 4 of 4

DocumentPublishedAction
Previous/Parent decision notice: - Parent decision notice (Ref: 19/01244/OUT)DCPRDEC5 Jul 2021View
Application Form: ApplicationDCAPFORM23 Dec 2025View
Application Supporting Document: Water Scheme Full Planning Condition Discharge Letter (2)DCSUPDOC23 Dec 2025View
57567_Decision_Notice_-_DETERMINED_DISCHG.pdfDCDEC10 Mar 2026View

Documents open on the council website. Browse council documents if a link has changed.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Received date

    Published milestoneCouncil source
  2. Registration date

    Published milestoneCouncil source
  3. Consultation expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  4. Statutory expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  5. Dispatch date

    Published milestoneCouncil source
  6. Decision date

    Published milestoneCouncil source
  7. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  8. Application date

    Published milestoneCouncil source

Decision & conditions

Determined
Previous/Parent decision notice: - Parent decision notice (Ref: 19/01244/OUT) 57567_Decision_Notice_-_DETERMINED_DISCHG.pdf
Planning conditions
  1. Discharge of condition C15 (fire hydrants) pursuant to outline permission 19/01244/OUT Notwithstanding the submitted information no development above ground works shall take place until provision has been made for fire hydrants in accordance with a scheme to be submitted to and approved in writing by the Local Planning Authority. The scheme shall thereafter be implemented in accordance with the approved details. Prior to the first occupation of any dwelling/building to be served by the scheme, written confirmation shall be submitted to and approved in writing by the Local Planning Authority that the scheme has been implemented in full and is certified as being ready for use. Reason: In the interest of community safety and to ensure that adequate supplies are available for fire fighting to support policy LP16 of the adopted Peterborough Local Plan (2019). Plans submitted in support of the partial discharge of condition 15 under 22/01632/DISCHG - Scheme Development Plan (Drawing Number: 198164/1/0160650) (dated 14th April 2023 / received 28th June 2023) Approved documents/details: - Letter dated 18.11.2025, Cambridgeshire Fire and Rescue Service, Water and Planning Manager Assessment: Condition 15 was partially discharged under 22/01632/DISCHG, where the scheme was secured in accordance with the first section of the condition. The second section of the condition required written confirmation be submitted to and approved by the Local Planning Authority. The Water and Planning Manager from Cambridgeshire Fire and Rescue Service has confirmed that following an inspection of the development, the fire hydrants requested have been installed and were found in a satisfactory condition and ready for operational use. Therefore, the second section of the condition has been satisfied and the condition is now fully discharged. Conclusion: Subject to satisfactory implementation on site this condition is hereby discharged.
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.