RefusedCouncil status: Decided

Proposed NTQ telecommunications installation. Proposed 20m High Valmont climbable monopole on 5.2 x 5.2 x 1.4m deep concrete base with config 2 circular headframe for 6No. Antennas Apertures at 30 degrees/170 degrees /280 degrees & 4No. 600 degrees dishes. BOB's, MHA's and active routers to be fixed to headframe behind Antennas and associated ancillary works.

Rhodes Bank Land To The South Of Roscoe Street Car Park Oldham OL1 1EA

Oldham Metropolitan Borough CouncilReference TEL/351889/23Telecommunications

Last published check: 14 Nov 2026, 07:58. Check the council record for more recent changes.

Status and dates

Last published check: 14 Nov 2026, 07:58 (UK)

  1. DoneReceived6 Nov 2023
  2. DoneValidated6 Nov 2023
  3. ClosedConsultationEnded 22 Dec 2023
  4. Date set by councilTarget decision date26 Dec 2023
  5. DecidedPrior Approval Required and Refused22 Dec 2023

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (13)
  1. Application Received Date

    Published milestoneCouncil source
  2. Application Validated Date

    Published milestoneCouncil source
  3. Latest Neighbour Consultation Date

    Published milestoneCouncil source
  4. Last Site Notice Posted Date

    Published milestoneCouncil source
  5. Neighbour Consultation Expiry Date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  6. Decision Issued Date

    Published milestoneCouncil source
  7. Decision Made Date

    Published milestoneCouncil source
  8. Latest Site Notice Expiry Date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  9. Determination Deadline

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  10. Permission Expiry Date

    Published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Telecommunications
Ward
Saint Mary's
Documents
11 published

Proposal

Proposed NTQ telecommunications installation. Proposed 20m High Valmont climbable monopole on 5.2 x 5.2 x 1.4m deep concrete base with config 2 circular headframe for 6No. Antennas Apertures at 30 degrees/170 degrees /280 degrees & 4No. 600 degrees dishes. BOB's, MHA's and active routers to be fixed to headframe behind Antennas and associated ancillary works.

Reference
TEL/351889/23
Alternative references
PP-12571492
Ward
Saint Mary's
Agent
WHP Telecoms Limited

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • APPEAL START LETTERAppeal Correspondence30 Apr 2024View
  • GROUNDS OF APPEAL STATEMENTAppeal Correspondence15 Jan 2024View
  • OFFICER REPORTReport22 Dec 2023View
  • DN REQ REF TELECOMUNICATIONDecision22 Dec 2023View
  • APPLICATIONFORMREDACTEDApplication Form3 Nov 2023View
  • 1-9 1712593_OLM159_34557_M001_MBNL_NTQ_GA_APlans3 Nov 2023View
  • 34557 - ICNIRPGeneral Documents3 Nov 2023View
  • 34557 DEVELOPERS NOTICEPermitted development notice3 Nov 2023View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Prior Approval Required and Refused

Appeal status: Decided · Appeal Allowed

DN REQ REF TELECOMUNICATION

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.