ApprovedCouncil status: Decided

Application for Non-Material amendment to planning permission ref: PA/24/01755, Dated 31/10/2025.Non Material amendment(s) Sought: 1. Regulatory - Building shifted 300mm to the south of the site to increase the distance between the building and the northern site boundaryfrom 970mm to 1270mm.To mitigate BS9991 requirement for facades within 1000mm of the site boundary to be 120 mins fire rated from both sides and windows withinthe facade to be fire rated with a maximum area of 1sqm in line with BS9991 section 18.4 fig 20.2. Regulatory - Window sill raised 150mm from 675mm to 825mm and transom lowered 160mm from 1285mm to 1125 above FFL.To ensure compliance with Approved Documents Part M (for handle heights), Part K (for fall from height and climbable zones) and Part O (Cillheights).3. Design - Minor elevation amendments for balcony railings, brick detailing, precast banding and pavilion parapet.To align with window sill height change (item 2) and retain the design intent.4. - Spatial - Relocation and redesign of the substation and generator room, and subsequent landscaping changes. To avoid building substation and generator room on Thames Water sewer/easement zone.5. - Spatial - Adjustment of cycle parking allocation and location within the site. Reduction of 6 no. long stay cycle parking spaces.Due to relocation of substation and generator room (item 4), external long stay cycle parking was reallocated elsewhere in the site. Insufficientspace to re-provide 6 no. Covered long term cycle spaces within the courtyard without detriment to the landscape design. Proposed provisionis in excess of the GLA's revised cycle requirements published within the 'Support for housebuilding London Plan' published March 2026.6. - Design - Removal of circular columns to pavilion balconies. Columns are not required to support balcony following change to bolt-on balcony system.7. - Design - Perforated screen to cycle/refuse stores along Hawthorn lane replaced with solid profiled rainscreen panel and louvred door.Following Secured by Design guidance to achieve LPS 1175 or equivalent rating to cycle/refuse store doors and minimise risk of theft due tocycles being visible from street.8. - Design - Bathroom window on north and south pavilion elevations omitted on levels 1-4. Design development due to clash between window and bathroom sanitaryware.9. - Spatial/Regulatory - General minor updates to core layout, apartments and party walls. To allow for core stair compliance with Approved Document K, riser size requirements, integration of POD bathrooms and PUC utilities.10. - Regulatory - Amendment to materiality of some communal doors. Changed from solid metal to glazed doors with canopies above to reflect the door's use as access to a communal corridor.

Clare House, 10 Hawthorn Avenue, London and Playground on Hawthorn Avenue, London, E3

London Borough of Tower HamletsReference PA/26/00964/SNon-material amendment (TCPA S96a)

Last published check: 13 Nov 2026, 10:47. Check the council record for more recent changes.

Status and dates

Last published check: 13 Nov 2026, 10:47 (UK)

  1. Not publishedReceivedNo date on council record
  2. DoneValidated4 Jun 2026
  3. Not publishedConsultationNo date on council record
  4. Not publishedTarget decision dateNo date on council record
  5. DecidedPermit5 Nov 2026

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (3)
  1. Application Validated Date

    Published milestoneCouncil source
  2. Decision Issued Date

    Published milestoneCouncil source
Application type
Non-material amendment (TCPA S96a)
Ward
Bow East
Documents
21 published

Proposal

Application for Non-Material amendment to planning permission ref: PA/24/01755, Dated 31/10/2025.Non Material amendment(s) Sought: 1. Regulatory - Building shifted 300mm to the south of the site to increase the distance between the building and the northern site boundaryfrom 970mm to 1270mm.To mitigate BS9991 requirement for facades within 1000mm of the site boundary to be 120 mins fire rated from both sides and windows withinthe facade to be fire rated with a maximum area of 1sqm in line with BS9991 section 18.4 fig 20.2. Regulatory - Window sill raised 150mm from 675mm to 825mm and transom lowered 160mm from 1285mm to 1125 above FFL.To ensure compliance with Approved Documents Part M (for handle heights), Part K (for fall from height and climbable zones) and Part O (Cillheights).3. Design - Minor elevation amendments for balcony railings, brick detailing, precast banding and pavilion parapet.To align with window sill height change (item 2) and retain the design intent.4. - Spatial - Relocation and redesign of the substation and generator room, and subsequent landscaping changes. To avoid building substation and generator room on Thames Water sewer/easement zone.5. - Spatial - Adjustment of cycle parking allocation and location within the site. Reduction of 6 no. long stay cycle parking spaces.Due to relocation of substation and generator room (item 4), external long stay cycle parking was reallocated elsewhere in the site. Insufficientspace to re-provide 6 no. Covered long term cycle spaces within the courtyard without detriment to the landscape design. Proposed provisionis in excess of the GLA's revised cycle requirements published within the 'Support for housebuilding London Plan' published March 2026.6. - Design - Removal of circular columns to pavilion balconies. Columns are not required to support balcony following change to bolt-on balcony system.7. - Design - Perforated screen to cycle/refuse stores along Hawthorn lane replaced with solid profiled rainscreen panel and louvred door.Following Secured by Design guidance to achieve LPS 1175 or equivalent rating to cycle/refuse store doors and minimise risk of theft due tocycles being visible from street.8. - Design - Bathroom window on north and south pavilion elevations omitted on levels 1-4. Design development due to clash between window and bathroom sanitaryware.9. - Spatial/Regulatory - General minor updates to core layout, apartments and party walls. To allow for core stair compliance with Approved Document K, riser size requirements, integration of POD bathrooms and PUC utilities.10. - Regulatory - Amendment to materiality of some communal doors. Changed from solid metal to glazed doors with canopies above to reflect the door's use as access to a communal corridor.

Reference
PA/26/00964/S
Ward
Bow East

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • DECISION_NOTICEDecision Notice5 Nov 2026View
  • OFFICERS REPORTDelegated Report5 Nov 2026View
  • S96A NMA REPORTReport17 Sept 2026View
  • S96A NMA REPORT - APPENDIXReport17 Sept 2026View
  • NMA REPORTReport3 Sept 2026View
  • BUILDING SAFETY REGULATORConsultee Comment29 Jun 2026View
  • Application FormApplication Form4 Jun 2026View
  • PROPOSED SECOND FLOOR PLANCurrent Plan4 Jun 2026View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Permit
DECISION_NOTICE
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.