RefusedCouncil status: The decision has been made on the application.

Install bike store to front. Lengthen side window. Air conditioning unit and Air Source Heat Pump to rear with raised window sill. Side dormer roof extension and roof lights.

1 Trinder Mews Teddington TW11 8HY

London Borough of Richmond upon ThamesReference PA26/1974Householder Application

Last published check: 3 Oct 2026, 05:50. Check the council record for more recent changes.

Status and dates

Last published check: 3 Oct 2026, 05:50 (UK)

  1. DoneReceived5 Jun 2026
  2. DoneValidated10 Jun 2026
  3. ClosedConsultationEnded 2 Jul 2026
  4. Date set by councilTarget decision date5 Aug 2026
  5. DecidedRefused Permission3 Aug 2026

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (13)
  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Registration date

    Published milestoneCouncil source
  4. Valid date

    Published milestoneCouncil source
  5. Press notice start date

    Published milestoneCouncil source
  6. Site notice date

    Published milestoneCouncil source
  7. Consultation expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  8. Statutory expiry date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  9. Publicity end date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  10. Site notice end date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  11. Dispatch date

    Published milestoneCouncil source
  12. Decision date

    Published milestoneCouncil source
  13. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Householder Application
Ward
Hampton Wick & South Teddington Ward [HPK], Teddington Ward [TDD]
Documents
20 published

Proposal

Install bike store to front. Lengthen side window. Air conditioning unit and Air Source Heat Pump to rear with raised window sill. Side dormer roof extension and roof lights.

Reference
PA26/1974
Alternative references
PP-14984088
Ward
Hampton Wick & South Teddington Ward [HPK], Teddington Ward [TDD]
Agent
O Keeffe
UPRN
10002255480

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • Application Form - Without Personal DataApplication Form - Redacted5 Jun 2026View
  • Existing Ground & First Floor Plans ref.: 01Submitted Drawing5 Jun 2026View
  • Existing Second Floor & Roof Plan ref.: 02Submitted Drawing5 Jun 2026View
  • Existing Front & Rear Elevations ref.: 03Submitted Drawing5 Jun 2026View
  • Existing Left & Right Elevations ref.: 04Submitted Drawing5 Jun 2026View
  • Existing Sections AA BB ref.: 05Submitted Drawing5 Jun 2026View
  • Proposed Ground & First Floor Plans ref.: 08 Rev BSubmitted Drawing5 Jun 2026View
  • Proposed Second Floor & Roof Plan ref.: 09 Rev ASubmitted Drawing5 Jun 2026View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Refused Permission
Decision
Planning conditions
  1. The proposed side dormer, by reason of its design and location, would cause undue overlooking and loss of privacy which is detrimental to the amenities of occupants of neighbouring residential properties and therefore the scheme is contrary to Policy 46 of the adopted Local Plan (2025) and the Supplementary Planning Document (SPD) on House Extensions and External Alterations.
  2. For the avoidance of doubt the Drawing(s) No(s) and Document(s) to which this decision refers are as follows:- Email named Agent’s Suggestion received 02/07/2026. FIRE STRATEGY STATEMENT Flood information Design, access and heritage statement Existing Ground & First Floor Plans ref.: 01 Existing Second Floor & Roof Plan ref.: 02 Existing Front & Rear Elevations ref.: 03 Existing Left & Right Elevations ref.: 04 Existing Sections AA BB ref.: 05 Proposed Ground & First Floor Plans ref.: 08 Rev B Proposed Second Floor & Roof Plan ref.: 09 Rev A Proposed Front & Rear Elevations ref.: 10 Rev A Proposed Left & Right Elevations ref.: 11 Rev B Proposed Sections AA BB ref.: 12 Fire Safety Diagram ref.: 8A Location plan – all received 5 June 2026. Combined Air Source Heat Pump & Air Conditioning Sound Assessment dated 29 November 2025.
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.