Council planning record

Loft conversion with rear dormer. Two front rooflights / removal of chimney stack. (Summary).

4, Spencer Road, Seven Kings, Ilford, IG3 8PW

A decision on this application has been issued.Reference: 1736/26London Borough of Redbridge

Last published check: 30 Sept 2026, 19:31. Check the council record for more recent changes.

Application location

4, Spencer Road, Seven Kings, Ilford, IG3 8PW

This record has no verified map location.

Application summary

Status
A decision on this application has been issued.
Application type
Cert. Lawfulness Proposed
Received
1 Jul 2026
Validated
2 Jul 2026
Determination deadline
26 Aug 2026
Local authority
London Borough of Redbridge

Application overview

Loft conversion with rear dormer. Two front rooflights / removal of chimney stack. (Summary).

Proposal details

Reference
1736/26
Alternative references
PP-15051589
Ward
Seven Kings
Agent
DURRANI
UPRN
100022236580

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents 15 of 15

DocumentPublishedAction
ApplicationFormRedacted.pdfApplication form1 Jul 2026View
PL11.pdfProposed plan1 Jul 2026View
PL10.pdfProposed plan - elevation1 Jul 2026View
PL09.pdfProposed plan - elevation1 Jul 2026View
4SP_res.pdfFire statement1 Jul 2026View
PL08.pdfProposed plan - roof plan1 Jul 2026View
PL01.pdfSite/block plan1 Jul 2026View
PL07.pdfProposed plan - floor plan1 Jul 2026View
PL06.pdfProposed plan - floor plan1 Jul 2026View
PL05.pdfProposed plan - floor plan1 Jul 2026View
PL03.pdfExisting plan - elevation1 Jul 2026View
PL02.pdfExisting plan - floor plan1 Jul 2026View
location-plan-1781085710327.pdfSite/block plan1 Jul 2026View
20260820T080149.735643376643375Decision Certificate Proposed CERTPRL_4861_v1.pdfDecision notice20 Aug 2026View
20260820T075726.7484SROR.pdfOfficer report20 Aug 2026View

Documents open on the council website. Browse council documents if a link has changed.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Press notice start date

    Published milestoneCouncil source
  4. Registration date

    Published milestoneCouncil source
  5. Valid date

    Published milestoneCouncil source
  6. Dispatch date

    Published milestoneCouncil source
  7. Decision date

    Published milestoneCouncil source
  8. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source

Decision & conditions

Lawful
20260820T080149.735643376643375Decision Certificate Proposed CERTPRL_4861_v1.pdf
Planning conditions
  1. in accordance with submitted plans PL01/PL02/PL03/PL04/PL05/PL06/PL07/PL08/PL09/PL10/PL11, location Plan / Rear Exception Statement & rear photos
  2. Schedule 2 Part 1 Class B of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies Must not exceed height of highest part of existing roof – Complies Must not extend beyond the plane of any existing roof slope which forms the principal elevation of the dwellinghouse and fronts a highway - complies Maximum volume is 40m3 for terrace houses and 50 m3 in other cases - Volume of rear dormer W= 3.48m D= 5.51 m H= 2.29m = 44.10 m3 / 2 = 22.05m3 < 50 m3 Must not involve installation, alteration or replacement of a veranda, balcony or raised platform, microwave antenna, chimney, flue or soil and vent pipe- Complies Must not be in a Conservation Area – Complies The materials used in any exterior work shall be of a similar appearance to those used in the construction of the exterior of the existing dwelling house – Complies Any window facing the side should be obscure glazed and non-opening up to 1.7 m above the floor – Complies The roof pitch should match the pitch of the original dwelling as far as practicable – Complies Other than in the case of a hip to gable enlargement, the edge of the enlargement closest to the eaves of the original roof shall, so far as is practicable, be not less than 20cm from the eaves of the original roof – complies Overall Conclusion : Permitted
  3. Schedule 2 Part 1 Class C of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies Does not protrude more than 0.15 metres beyond the plane of the slope of the original roof when measured from the perpendicular with the external surface of the original roof– Complies Must not be higher than the highest part of the original roof – Complies Must not include a chimney, flue or soil and vent pipe or solar photovoltaics or solar thermal equipment – Complies Any window facing the side should be obscure glazed and non-opening up to 1.7 metres above the floor of the room in which the window is installed- Complies Sensitively located if in Conservation Area - Not applicable/not in Conservation Area. Overall Conclusion: Permitted
  4. Schedule 2 Part 1 Class G of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies Must not exceed the highest part of the roof by 1 m or more – Complies If in a Conservation Area must not extend beyond a wall fronting a highway and which is either a principal or a side elevation of original dwelling – Complies Overall Conclusion: Permitted
  5. The proposals constitute permitted development, by virtue of Schedule 2 Article 3, Part 1, Class B, Class C, and Class G of the Town and Country Planning (General Permitted Development) Order 2015 (as amended).
  6. Redbridge Planning Service adopts a positive and proactive approach when engaging with applicants/agents in line with the National Planning Policy Framework. We encourage engagement with the pre-application service to avoid delays in the planning process. https://www.redbridge.gov.uk/planning-and-building/planning/
  7. The applicant should be aware that Building Regulations approval will be required for most types of building work. Please see information and how to apply for Building Regulation consent at: https://www.redbridge.gov.uk/planning-and-building/building-control/ or for further assistance contact the Building Control Section. e-mail: Buildingcontrol@redbridge.gov.uk Telephone: 020 8708 2529.
  8. Party Wall Act (1996) If you intend to carry out building work which involves one of the following categories:- * Work on an existing wall or structure shared with another property (section 2 of the Act). * Building a free standing wall or a wall of a building up to or astride the boundary with a neighbouring property (section 1 of the Act). * Excavation near a neighbouring building (section 6 of the Act). You must find out whether that work falls within the Act. If it does, you must notify all affected neighbours. An explanatory booklet is available here: https://www.gov.uk/government/publications/preventing-and-resolving-disputes-in-relation-to-party-walls/the-party-wall-etc-act-1996-explanatory-booklet.
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.