Status on council recordCouncil status: A decision on this application has been issued.

Loft Conversion with rear dormer. Two front rooflights. Detached rear outbuilding. (summary)

234, Ashurst Drive, Ilford, IG6 1EW

London Borough of RedbridgeReference 1548/26Cert. Lawfulness Proposed

Last published check: 2 Oct 2026, 08:04. Check the council record for more recent changes.

Status and dates

Last published check: 2 Oct 2026, 08:04 (UK)

  1. DoneReceived9 Jun 2026
  2. DoneValidated16 Jun 2026
  3. Not publishedConsultationNo date on council record
  4. Date set by councilTarget decision date4 Aug 2026
  5. Not yet publishedDecisionNo decision on council record

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (8)
  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Registration date

    Published milestoneCouncil source
  4. Press notice start date

    Published milestoneCouncil source
  5. Valid date

    Published milestoneCouncil source
  6. Dispatch date

    Published milestoneCouncil source
  7. Decision date

    Published milestoneCouncil source
  8. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Cert. Lawfulness Proposed
Ward
Aldborough
Documents
23 published

Proposal

Loft Conversion with rear dormer. Two front rooflights. Detached rear outbuilding. (summary)

Reference
1548/26
Alternative references
PP-14969575
Ward
Aldborough
Agent
Ahmad
UPRN
100022194733

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • ApplicationFormRedacted.pdfApplication form9 Jun 2026View
  • (02 June 2026) 234 Ashurst Drive_SITE BLOCK PLAN.pdfSite/block plan9 Jun 2026View
  • (02 June 2026) 234 Ashurst Drive_Loft Conversion(Page01).pdfExisting plan - floor plan9 Jun 2026View
  • (02 June 2026) 234 Ashurst Drive_Loft Conversion(Page02).pdfExisting plan - elevation9 Jun 2026View
  • GroundProposed plan - floor plan9 Jun 2026View
  • First floorProposed plan - floor plan9 Jun 2026View
  • LoftProposed plan - floor plan9 Jun 2026View
  • (02 June 2026) 234 Ashurst Drive_Loft Conversion(Page06).pdfProposed plan - roof plan9 Jun 2026View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Lawful
2079513_Decision_Certificate_Proposed_CERTPRL.pdf
Planning conditions
  1. in accordance with plans 234_AD_PA_01, 34_AD_PD_01, 34_AD_PD_01, 234_AD_PD_02, 234_AD_PA_02, 34_AD_PA_03 (Proposed Ground Floor Plan), 34_AD_PA_03 (Proposed Outbuilding Elevations), 234_AD_PD_04 (Proposed First Floor Plan), 234_AD_PA_04 (Existing and Proposed Block Plans), 234_AD_PD_05, 234_AD_PD_06, 234_AD_PD_07, 234_AD_PD_08
  2. Schedule 2 Part 1 Class B of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies Must not exceed height of highest part of existing roof – Complies Must not extend beyond the plane of any existing roof slope which forms the principal elevation of the dwellinghouse and fronts a highway - complies Maximum volume is 40m3 for terrace houses and 50 m3 in other cases - Rear Dormer W 5.45m X D 3.72m X H 2.56m = 51.9m3/2 = 25.95m3 Must not involve installation, alteration or replacement of a veranda, balcony or raised platform, microwave antenna, chimney, flue or soil and vent pipe- Complies Must not be in a Conservation Area – Complies The materials used in any exterior work shall be of a similar appearance to those used in the construction of the exterior of the existing dwelling house – Complies Any window facing the side should be obscure glazed and non-opening up to 1.7 m above the floor – Complies The roof pitch should match the pitch of the original dwelling as far as practicable – Complies Other than in the case of a hip to gable enlargement, the edge of the enlargement closest to the eaves of the original roof shall, so far as is practicable, be not less than 20cm from the eaves of the original roof – complies Overall Conclusion : Permitted
  3. Schedule 2 Part 1 Class C of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies Does not protrude more than 0.15 metres beyond the plane of the slope of the original roof when measured from the perpendicular with the external surface of the original roof– Complies Must not be higher than the highest part of the original roof – Complies Must not include a chimney, flue or soil and vent pipe or solar photovoltaics or solar thermal equipment – Complies Any window facing the side should be obscure glazed and non-opening up to 1.7 metres above the floor of the room in which the window is installed- Complies Sensitively located if in Conservation Area - Not applicable/not in Conservation Area. Overall Conclusion: Permitted
  4. Schedule 2 Part 1 Class E of The Town and Country Planning (General Permitted Development) (England) Order 2015 (as amended). Permission to use the dwellinghouse as a dwellinghouse was not granted only by virtue of Class M, N, P, or Q of Schedule 2 Part 3 (change of use) - complies No more than 50% of the curtilage of the original dwelling may be covered by buildings, enclosures and containers – Complies No part of the building, enclosure, pool or container would be situated on land forward of a wall forming the principal elevation of the original dwellinghouse – Complies Must not have more than one storey – Complies Maximum roof height is 4 m if dual pitched – Complies Maximum roof height within 2 m of the boundary is 2.5 m – Complies Maximum roof height is 3 m for all other cases – Complies Height of eaves cannot exceed 2.5 m – Complies Would not be used as a dwelling – complies Must not involve provision or construction of a veranda, balcony or raised platform or microwave antenna – Complies Must not exceed 3,500 litres if a container – Complies If In a Conservation Area must not be to the side of the dwelling – Complies Not subject to an Article 4 Direction – Complies Not within the curtilage of a Listed Building Overall Conclusion: Permitted
  5. The proposals constitute permitted development, by virtue of Schedule 2 Article 3, Part 1, Class B, C and E of the Town and Country Planning (General Permitted Development) Order 2015 (as amended).
  6. Redbridge Planning Service adopts a positive and proactive approach when engaging with applicants/agents in line with the National Planning Policy Framework. We encourage engagement with the pre-application service to avoid delays in the planning process. https://www.redbridge.gov.uk/planning-and-building/planning/
  7. The applicant should be aware that Building Regulations approval will be required for most types of building work. Please see information and how to apply for Building Regulation consent at: https://www.redbridge.gov.uk/planning-and-building/building-control/ or for further assistance contact the Building Control Section. e-mail: Buildingcontrol@redbridge.gov.uk Telephone: 020 8708 2529.
Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.