Demolition of existing single storey conservatory extension and erection of new single storey extension. Formation of openings for new door and internal glazed screen at base of lower ground floor stairs and replacement of engineered timber floor coverings to lower ground floor with engineered timber floor. Re paving of rear patio and isolated repairs to masonry and pointing.
173 Liverpool Road, London, N1 0RF
FINAL DECISIONReference: P2026/1705/LBCLondon Borough of Islington
Last published check: 29 Sept 2026, 16:13. Check the council record for more recent changes.
Application location
173 Liverpool Road, London, N1 0RF
This record has no verified map location.
Application summary
Status
FINAL DECISION
Application type
Listed Building
Received
29 Jun 2026
Validated
8 Jul 2026
Determination deadline
1 Sept 2026
Local authority
London Borough of Islington
Application overview
Demolition of existing single storey conservatory extension and erection of new single storey extension. Formation of openings for new door and internal glazed screen at base of lower ground floor stairs and replacement of engineered timber floor coverings to lower ground floor with engineered timber floor. Re paving of rear patio and isolated repairs to masonry and pointing.
Proposal details
Reference
P2026/1705/LBC
Alternative references
PP-15009818_C
Ward
Barnsbury
Agent
Stephen Evans
UPRN
5300057147
Sign in to view all collected council fields and recorded changes.
3 YEAR CONSENT PERIOD FOR LBC and CAC: The works hereby permitted shall be begun not later than three years from the date of this consent. REASON: To comply with the provisions of Section 18(1)(a) of the Planning (Listed Buildings and Conservation Areas) Act 1990 as amended by the Planning and Compulsory Purchase Act 2004 (Chapter 5).
WORKS AND FINISHES (COMPLIANCE): All new external and internal works and finishes and works of making good to the retained fabric shall match the existing adjacent work with regard to the methods used and to material, colour, texture and profile. Bricks shall be reused from lowered section of the wall. All such works and finishes shall be maintained as such thereafter. REASON: In order to safeguard the special architectural or historic interest of the heritage asset.
ENGINEER’S REPORT (DETAILS): The proposed works to tie in the third-floor front elevation to stabilize the bulging masonry shall not take place until an engineer’s report outlining the methodology and demonstrating that there will be no damage to the building or surrounding buildings and structures is submitted to and approved in writing by the Local Planning Authority. The development shall be carried out strictly in accordance with the approved details and retained a such thereafter. REASON: In order to safeguard the special architectural or historic interest of the heritage asset.
847 L02 Revision 00; 847 L11 Revision 04; 847-D01.01_Heritage Design and Access Statement dated 17 August 2026; 847-D02.00_Sustainability Statement dated 29 June 2026.
LISTED BUILDING CONSENT ONLY: This consent relates solely to listed building matters. Should it become necessary to make alterations to the consented scheme in order to comply with other legislation, such as Building Regulations, a further consent may be required. Such a consent should be sought and obtained prior to the relevant works being undertaken.