Awaiting decisionCouncil status: VALIDATED

We wish the condition to be removed, because the results of further site investigations support our original proposal to raise the coal vault door opening height. As part of clearing other conditions for the Listed Building consent, a site investigation has been carried out of the coal vault entrance door lintel. It was revealed that there is no existing historic brick arch above the entrance, as would be expected if it was original, and instead a concrete lintel was found. Please refer to Chelmer Global Ltd Factual report: 'FACT14165 (rev1).pdf' page.3 'Sketch Site Plan' and page.14 'Photograph 5 - Opening Up 1 (OP1)'. The existing lintel to this internal coal vault is positioned lower down from the vaulted arch ceiling behind, than the higher positioned lintel to the external coal vault. Please refer to existing drawing GB-SA-DR-A-3010-2001 view: 'East Front Lightwell' and GB-SA-DR-A-3010-2001. We propose that the entrance opening height to be raised by 100mm by replacing the concrete lintel in accordance with the structural engineer's design, method and specification. Please refer to detail drawing GB-SA-DR-A-4030-5002, and structural engineer's documents: '4350.02 - Design Intent Report.pdf' and '4350 - Specification.pdf'. This change to the internal coal vault opening would bring it in line with external coal vault opening and the head would remain below the vaulted ceiling behind. Please refer to proposed drawings GB-SA-DR-A-4030-3003 view: 'East Front Lightwell' and GB-SA-DR-A-4030-2001. The proposed height of the door opening would be 1.7m, which will remain clearly subordinate to the height of the main doors of house and not alter the vault's historic characteristically low entrance height. Please refer to other drawings updated accordingly: GB-SA-DR-A-3010-1209 - PLAN LOWER GROUND LEVEL EXISTING GB-SA-DR-A-3010-1210 - PLAN GROUND LEVEL EXISTING GB-SA-DR-A-3010-2001 - ELEVATION WEST EXISTING GB-SA-DR-A-3010-3001 - SECTIONS 1 EXISTING GB-SA-DR-A-3010-3002 - SECTION 2 EXISTING GB-SA-DR-A-3010-3003 - SECTION 3-4-5-6 EXISTING GB-SA-DR-A-4030-1009 - PLAN LOWER GROUND LEVEL PROPOSED GB-SA-DR-A-4030-1010 - PLAN GROUND LEVEL PROPOSED GB-SA-DR-A-4030-2001 - ELEVATION WEST PROPOSED GB-SA-DR-A-4030-3001 - SECTION 1 PROPOSED GB-SA-DR-A-4030-3002 - SECTION 2 PROPOSED GB-SA-DR-A-4030-3003 - SECTION 3-4-5-6 PROPOSED GB-SA-DR-A-4030-5002 - SECTION DOOR HEAD CONSTRUCTION EXISTING & PROPOSED Further photos of door opening lintel: 46GS_SI_CVbefore.jpg 46GS_SI_CVhole2.jpg 46GS_SI_CVhole3.jpg 46GS_SI_CVholeunder1.jpg

46, Gibson Square, London, N1 0RA

London Borough of IslingtonReference P2025/3632/S73Removal/Variation of Condition (Section 73)

Last published check: 4 Oct 2026, 11:02. Check the council record for more recent changes.

Status and dates

Last published check: 4 Oct 2026, 11:02 (UK)

288days past target decision date11 Feb 2026 · decision not yet published

  1. DoneReceived18 Dec 2025
  2. DoneValidated19 Mar 2026
  3. Not publishedConsultationNo date on council record
  4. Overdue · 288 daysTarget decision date11 Feb 2026
  5. Not yet publishedDecisionNo decision on council record

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (5)
  1. Application date

    Published milestoneCouncil source
  2. Received date

    Published milestoneCouncil source
  3. Registration date

    Published milestoneCouncil source
  4. Decision due date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  5. Valid date

    Published milestoneCouncil source
Application type
Removal/Variation of Condition (Section 73)
Ward
St Mary's & St James'
Documents
0 published

Proposal

We wish the condition to be removed, because the results of further site investigations support our original proposal to raise the coal vault door opening height. As part of clearing other conditions for the Listed Building consent, a site investigation has been carried out of the coal vault entrance door lintel. It was revealed that there is no existing historic brick arch above the entrance, as would be expected if it was original, and instead a concrete lintel was found. Please refer to Chelmer Global Ltd Factual report: 'FACT14165 (rev1).pdf' page.3 'Sketch Site Plan' and page.14 'Photograph 5 - Opening Up 1 (OP1)'. The existing lintel to this internal coal vault is positioned lower down from the vaulted arch ceiling behind, than the higher positioned lintel to the external coal vault. Please refer to existing drawing GB-SA-DR-A-3010-2001 view: 'East Front Lightwell' and GB-SA-DR-A-3010-2001. We propose that the entrance opening height to be raised by 100mm by replacing the concrete lintel in accordance with the structural engineer's design, method and specification. Please refer to detail drawing GB-SA-DR-A-4030-5002, and structural engineer's documents: '4350.02 - Design Intent Report.pdf' and '4350 - Specification.pdf'. This change to the internal coal vault opening would bring it in line with external coal vault opening and the head would remain below the vaulted ceiling behind. Please refer to proposed drawings GB-SA-DR-A-4030-3003 view: 'East Front Lightwell' and GB-SA-DR-A-4030-2001. The proposed height of the door opening would be 1.7m, which will remain clearly subordinate to the height of the main doors of house and not alter the vault's historic characteristically low entrance height. Please refer to other drawings updated accordingly: GB-SA-DR-A-3010-1209 - PLAN LOWER GROUND LEVEL EXISTING GB-SA-DR-A-3010-1210 - PLAN GROUND LEVEL EXISTING GB-SA-DR-A-3010-2001 - ELEVATION WEST EXISTING GB-SA-DR-A-3010-3001 - SECTIONS 1 EXISTING GB-SA-DR-A-3010-3002 - SECTION 2 EXISTING GB-SA-DR-A-3010-3003 - SECTION 3-4-5-6 EXISTING GB-SA-DR-A-4030-1009 - PLAN LOWER GROUND LEVEL PROPOSED GB-SA-DR-A-4030-1010 - PLAN GROUND LEVEL PROPOSED GB-SA-DR-A-4030-2001 - ELEVATION WEST PROPOSED GB-SA-DR-A-4030-3001 - SECTION 1 PROPOSED GB-SA-DR-A-4030-3002 - SECTION 2 PROPOSED GB-SA-DR-A-4030-3003 - SECTION 3-4-5-6 PROPOSED GB-SA-DR-A-4030-5002 - SECTION DOOR HEAD CONSTRUCTION EXISTING & PROPOSED Further photos of door opening lintel: 46GS_SI_CVbefore.jpg 46GS_SI_CVhole2.jpg 46GS_SI_CVhole3.jpg 46GS_SI_CVholeunder1.jpg

Reference
P2025/3632/S73
Alternative references
PP-14570504
Ward
St Mary's & St James'
Agent
Jeremy Scott
UPRN
5300035321

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

No documents match this view.

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Decision not yet published
Planning conditions

We haven’t collected any decision conditions for this application.

Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.