Remove all non-compliant former ACM cladding zones (Wall Type 1), areas constructed with an EPS-based insulated render system (Wall Type 2), and traditional cavity brickwork zones that contain combustible PIR insulation (Wall Type 3, reinstate proper fire compartmentation and install new A1/A2s1, d0-rated systems, balcony remediation, replacement of spandrel panels and reinstatement of continuous cavity barriers.
St Davids Apartments, 53 Lough Road, London, N7 8BZ
Remove all non-compliant former ACM cladding zones (Wall Type 1), areas constructed with an EPS-based insulated render system (Wall Type 2), and traditional cavity brickwork zones that contain combustible PIR insulation (Wall Type 3, reinstate proper fire compartmentation and install new A1/A2s1, d0-rated systems, balcony remediation, replacement of spandrel panels and reinstatement of continuous cavity barriers.
Reference
P2025/3590/FUL
Alternative references
PP-14551526
Ward
Laycock
Agent
Mr Richard Hughes
UPRN
10090264545
Sign in to view all collected council fields and recorded changes.
3 YEAR CONSENT PERIOD: The development hereby permitted shall be begun not later than the expiration of three years from the date of this permission. REASON: To comply with the provisions of Section 91(1)(a) of the Town and Country Planning Act 1990 as amended by the Planning and Compulsory Purchase Act 2004 (Chapter 5).
DRAWING AND DOCUMENT NUMBERS: The development hereby approved shall be carried out in accordance with the following approved plans: Site Location Plan, Proposed Site Plan 10091-BBS-ZZ-ZZ-DR-A-10100 Rev P.01, Proposed Lower Ground Floor 10091- BBS- ZZ- LG- DR- A- 11100 Rev P.01, Proposed Ground Floor 10091-BBS-ZZ-00-DR-A-11101 Rev P.01, Proposed First Floor 10091- BBS- ZZ- 01- DR- A- 11102 Rev P.01, Proposed Second Floor 10091- BBS- ZZ- 02- DR- A- 11103 Rev P.01, Proposed Third Floor 10091- BBS- ZZ- 03- DR- A- 11104 Rev P.01, Proposed Fourth Floor 10091- BBS- ZZ- 04- DR- A- 11105 Rev P.01, Proposed Fifth Floor 10091- BBS- ZZ- 05- DR- A- 11106 Rev P.01, Proposed Sixth Floor 10091- BBS- ZZ- 06- DR- A- 11107 Rev P.01, Proposed Roof Plan 10091- BBS- ZZ- RF- DR- A- 11108 Rev P.01, Proposed Elevation – East 10091-BBS-ZZ-ZZ-DR-A-12100 Rev P.01, Proposed Elevation -West 10091-BBS-ZZ-ZZ-DR-A-12101 RevP.01, Proposed Elevation – North 10091-BBS-ZZ-ZZ-DR-A-12102 Rev P.01, Proposed Elevation – South 10091-BBS-ZZ-ZZ-DR-A-12103 Rev P.01, Design & Access Statement 10091-BBS-XX-XX-RP-A-00001 Rev P. 01 – December 2025, Sustainable Design & Construction Statement 10091-BBS-ZZ-ZZ-RP-A-00002 Rev P.01 – January 2026, Fire Strategy Report by Firntec, Fire Statement by MetroSafety, Cover Letter REASON: To comply with Section 70(1)(a) of the Town and Country Act 1990 as amended and the Reason for Grant and also for the avoidance of doubt and in the interest of proper planning.
MATERIALS (COMPLIANCE): The development shall be constructed in accordance with the schedule of materials noted on the approved plans and within the Design and Access Statement. The development shall be carried out strictly in accordance with the details so approved and shall be maintained as such thereafter. REASON: In the interest of securing sustainable development and to ensure that the resulting appearance and construction of the development is of a high standard.