Council planning record

Condition 10:Greenfield Community College - New System - EW.pdf - Solar For Schools design information pack.Greenfield Academy - SolarForSchools - layout.pdf - Updated drawing of PV layout coordinated with other roof penetrations.DS_20231219_SG36_40_50CX-P2_Datasheet_V4_EN.pdf - Datasheet for PV Panel InverterCondition 15:External Plant:LA002-GEM-01-RF-D-Z-5001.pdf - Teaching Block Roof Plan showing PlantLA002-GEM-03-01-D-M-5001 - Sport Block Plantroom.pdf - Sport Block Roof Plan showing PlantLA002-GEM-XX-00-D-Z-5001 - Energy Centre.pdf - Energy Centre Layout showing PlantM6as-RAV-GM1101ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Teaching Block x3 unitsCAHV-R450YA-HPB_Product_Information_Sheet(2).pdf - ASHP for Sports Block x2 unitsM6as-RAV-GM301ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Sports Block x1 unitEAHV-M1500YCL-N.pdf - ASHP for Energy Centre x2 unitsInternal Plant:LA002-GEM-01-00-D-M-5701 Ground Floor Ventilation.pdf - GF Teaching BlockLA002-GEM-01-01-D-M-5701 First Floor Ventilation.pdf - FF Teaching BlockLA002-GEM-01-02-D-M-5701 Second Floor Ventilation.pdf - SF Teaching BlockLA002-GEM-03-00-D-M-5701.pdf - Sport Block Block Ventilation LayoutNuaire MVHR Extract Fans.pdf - Heat Recovery/Extract units within Teaching Block/Sports Block (locations stated on each page)HVR.pdf - Hybrid Ventilation Units in Teaching Rooms (connected to window vents)

Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF

DecidedReference: DM/26/00570/DRCDurham County Council

Last published check: 14 Oct 2026, 09:13. Check the council record for more recent changes.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Application Received Date

    Published milestoneCouncil source
  2. Application Validated Date

    Published milestoneCouncil source
  3. Standard Consultation Date

    Published milestoneCouncil source
  4. Latest Consultation Expiry Date

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  5. Determination Deadline

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  6. Decision Issued Date

    Published milestoneCouncil source
  7. Decision Made Date

    Published milestoneCouncil source
  8. Permission Expiry Date

    Published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source

Application summary

Status
Decided
Application type
Details Reserved by Condition
Received
6 Mar 2026
Validated
9 Mar 2026
Determination deadline
4 May 2026
Local authority
Durham County Council

Application overview

Condition 10:Greenfield Community College - New System - EW.pdf - Solar For Schools design information pack.Greenfield Academy - SolarForSchools - layout.pdf - Updated drawing of PV layout coordinated with other roof penetrations.DS_20231219_SG36_40_50CX-P2_Datasheet_V4_EN.pdf - Datasheet for PV Panel InverterCondition 15:External Plant:LA002-GEM-01-RF-D-Z-5001.pdf - Teaching Block Roof Plan showing PlantLA002-GEM-03-01-D-M-5001 - Sport Block Plantroom.pdf - Sport Block Roof Plan showing PlantLA002-GEM-XX-00-D-Z-5001 - Energy Centre.pdf - Energy Centre Layout showing PlantM6as-RAV-GM1101ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Teaching Block x3 unitsCAHV-R450YA-HPB_Product_Information_Sheet(2).pdf - ASHP for Sports Block x2 unitsM6as-RAV-GM301ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Sports Block x1 unitEAHV-M1500YCL-N.pdf - ASHP for Energy Centre x2 unitsInternal Plant:LA002-GEM-01-00-D-M-5701 Ground Floor Ventilation.pdf - GF Teaching BlockLA002-GEM-01-01-D-M-5701 First Floor Ventilation.pdf - FF Teaching BlockLA002-GEM-01-02-D-M-5701 Second Floor Ventilation.pdf - SF Teaching BlockLA002-GEM-03-00-D-M-5701.pdf - Sport Block Block Ventilation LayoutNuaire MVHR Extract Fans.pdf - Heat Recovery/Extract units within Teaching Block/Sports Block (locations stated on each page)HVR.pdf - Hybrid Ventilation Units in Teaching Rooms (connected to window vents)

Proposal details

Reference
DM/26/00570/DRC
Alternative references
PP-14745912
Ward
Aycliffe North And Middridge
Parish
Great Aycliffe
Agent
Howarth Litchfield

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Application location

Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF

This record has no verified map location.

View council map

Documents 3 of 3

DocumentPublishedAction
APPROVAL DRCDecision · PDF8 Jul 2026View
DRCDelegated Report · PDF8 Jul 2026View
APPLICATIONFORMREDACTEDApplication Form · PDF6 Mar 2026View

Documents open on the council website. Browse council documents if a link has changed.

Decision & conditions

Approved
APPROVAL DRC
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.