ApprovedCouncil status: Decided

Discharge of condition 3 (Noise attenuation) pursuant to application 21/01366 - Conversion of dwellinghouse into 2no. self contained flatsHush Acoustics - Hush-Mesh Fire wired dressed down the sides of the existing joists and across the back ofthe existing ceiling to form support tray for insulation12.5mm British Gypsum standard wallboard fixed to timber battens with 40mm British Gypsum DrywallScrews at 270mm centres in field of board, reducing to 150mm centres at board ends. Fixing to be at least10mm from bound edges and 13mm from cut edges. All boards to be taped and jointed before receiving wetBritish Gypsum Thistle plaster skim finish

9 Avenue Road Dover Kent CT16 2PX

Dover District CouncilReference CON/21/01366/AConditions

Last published check: 17 Oct 2026, 12:23. Check the council record for more recent changes.

Status and dates

Last published check: 17 Oct 2026, 12:23 (UK)

  1. DoneReceived28 Jul 2024
  2. DoneValidated30 Jul 2024
  3. Not publishedConsultationNo date on council record
  4. Date set by councilTarget decision date24 Sept 2024
  5. DecidedCondition Approved5 Sept 2024

Dates come from the council record. A target date passing does not confirm a decision.

All published dates (6)
  1. Application Received Date

    Published milestoneCouncil source
  2. Application Validated Date

    Published milestoneCouncil source
  3. Decision Issued Date

    Published milestoneCouncil source
  4. Decision Made Date

    Published milestoneCouncil source
  5. Determination Deadline

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
Application type
Conditions
Ward
St Radigunds
Parish
DOVER
Documents
1 published

Proposal

Discharge of condition 3 (Noise attenuation) pursuant to application 21/01366 - Conversion of dwellinghouse into 2no. self contained flatsHush Acoustics - Hush-Mesh Fire wired dressed down the sides of the existing joists and across the back ofthe existing ceiling to form support tray for insulation12.5mm British Gypsum standard wallboard fixed to timber battens with 40mm British Gypsum DrywallScrews at 270mm centres in field of board, reducing to 150mm centres at board ends. Fixing to be at least10mm from bound edges and 13mm from cut edges. All boards to be taped and jointed before receiving wetBritish Gypsum Thistle plaster skim finish

Reference
CON/21/01366/A
Ward
St Radigunds
Parish
DOVER

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Documents

  • 21003.B-050-A TYPICAL PARTY FLOOR CONSTRUCTION - FLOOR TYPE FL01Other28 Jul 2024View

Documents open on the council website. Browse council documents if a link has changed.

Decision and conditions

Condition Approved
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.