Discharge of condition 8 (Window detail) of application 25/01484/FUL (External work including re-roofing and thermal upgrade, access improvement and fire egress works including replacement of an external door and rehanging some existing doors for improved fire escape safety. Repairs to masonry and windows and structural repairs to the leaning south gable. Provision for ventilation and servicing penetrations and replacement glazing for thermal and fire upgrade) Supplementary information for discharge of condition 8. As illustrated on the proposed elevations, it is proposed to installed new sash windows, however a number of these are to be 60mns fire rated. The previous discharge of condition 8 did not address the fire rated windows, only the non-fire rated ones. See revised window detail now including details for fire rated screens. The proposed fire rated screens are designed to replicate a period sash window, with a 44mm false meeting rail and glazing bars. From the outside they read as sashes, they just don't have the offset between the two sashes. Drawing 308201-DKA-XX-XX-DR-A-400010 (revision C02) - New double glazed window details. S2309 H Mealing & Sons Ltd - Fire rated screens
Radstock Methodist Church, The Street, Radstock, BA3 3PL
Discharge of condition 8 (Window detail) of application 25/01484/FUL (External work including re-roofing and thermal upgrade, access improvement and fire egress works including replacement of an external door and rehanging some existing doors for improved fire escape safety. Repairs to masonry and windows and structural repairs to the leaning south gable. Provision for ventilation and servicing penetrations and replacement glazing for thermal and fire upgrade) Supplementary information for discharge of condition 8. As illustrated on the proposed elevations, it is proposed to installed new sash windows, however a number of these are to be 60mns fire rated. The previous discharge of condition 8 did not address the fire rated windows, only the non-fire rated ones. See revised window detail now including details for fire rated screens. The proposed fire rated screens are designed to replicate a period sash window, with a 44mm false meeting rail and glazing bars. From the outside they read as sashes, they just don't have the offset between the two sashes. Drawing 308201-DKA-XX-XX-DR-A-400010 (revision C02) - New double glazed window details. S2309 H Mealing & Sons Ltd - Fire rated screens
Reference
26/04027/COND
Alternative references
PP-15302422
Ward
Radstock
Parish
Radstock
Agent
DKA
UPRN
010001122713
Sign in to view all collected council fields and recorded changes.
Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.
Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.
Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.