Non Material Amendment to approved AWDM/0384/22 for changes to:A. Front Elevation:1.Minor realignment of front elevation walls to units B & F for buildability reasons.2.Amended bay window width to accommodate new disabled WC and relocation of kitchen to ground floor front elevation.3.Ground floor front elevation taller windows and doors replaced with shorter windows and 1metre brick apron to accommodate kitchen move to front elevation4.Front roof lights positions amended to accommodate en suite shower rooms.5.Corbelled brick band at head of ground floor brickwork omitted to simplify design.B. Rear Elevation6.Ground floor slide fold doors opening width amendment 4.2 to 3.2 mtrs with 3 no glazed door units. Solar gain issues and buildability.7.Roof dormer window widths increased to allow for Building Regulation insulation standards and structure requirements. Window sizes not amended8.Rear GF retractable sun canopies added to address solar gain issues.9.First floor windows minor position adjustments to accommodate bathrooms layouts.C Side Elevation10.Unit G side door entrance ground floor moved back from front corner to accommodate new kitchen layout with side window omitted.D. Landscape11.Ground level for housing reduced 150 millimetres with Datum of 5.4 in lieu of 5.55 as originally stated on landscape proposals. This maintains floor to ceiling heights as result of structural deeper floor zones.12.Boundary entry to Unit A and B combined to accommodate lamppost legal maintenance zone.
Land North Of 1 To 28 The Haven Brighton Road Lancing West Sussex
Non Material Amendment to approved AWDM/0384/22 for changes to:A. Front Elevation:1.Minor realignment of front elevation walls to units B & F for buildability reasons.2.Amended bay window width to accommodate new disabled WC and relocation of kitchen to ground floor front elevation.3.Ground floor front elevation taller windows and doors replaced with shorter windows and 1metre brick apron to accommodate kitchen move to front elevation4.Front roof lights positions amended to accommodate en suite shower rooms.5.Corbelled brick band at head of ground floor brickwork omitted to simplify design.B. Rear Elevation6.Ground floor slide fold doors opening width amendment 4.2 to 3.2 mtrs with 3 no glazed door units. Solar gain issues and buildability.7.Roof dormer window widths increased to allow for Building Regulation insulation standards and structure requirements. Window sizes not amended8.Rear GF retractable sun canopies added to address solar gain issues.9.First floor windows minor position adjustments to accommodate bathrooms layouts.C Side Elevation10.Unit G side door entrance ground floor moved back from front corner to accommodate new kitchen layout with side window omitted.D. Landscape11.Ground level for housing reduced 150 millimetres with Datum of 5.4 in lieu of 5.55 as originally stated on landscape proposals. This maintains floor to ceiling heights as result of structural deeper floor zones.12.Boundary entry to Unit A and B combined to accommodate lamppost legal maintenance zone.
Reference
AWDM/0079/23
Alternative references
PP-11862837
Ward
Widewater
Parish
Lancing Parish Council
Agent
CSarchitects
Sign in to view all collected council fields and recorded changes.
Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.
Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.
Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.