Council planning record

The approval of details reserved by conditions 3 (precise specifications or samples of the walling and roofing materials), 4 (any new masonry (including mortar) or materials shall match the existing materials in colour and texture), 5 (samples or detailed specifications of all external materials), 6 (New materials required for rebuild or repair to the Listed Building shall match the existing adjacent in respect of dimensions, colour, texture, face bond, and pointing), 7 ( sample panel(s) of all new facing work shall be provided on site showing the proposed - types, sizes, colour, texture face-bond pointing mortar mix, joint thickness and finish profile), 8 (method and extent of repointing), 9, (second-hand/salvaged materials), 10 (roofing sample panel), 11 (details of the treatment of verges and eaves), 12 (ventilation), 13 (roof lights), 14 (roof lights), 15 (rainwater goods), 16 (masonry cleaning), 17 (details of mortar mix), 18 (re-pointing mortar), 19 (windows and doors), 20 (trickle vents), 21 (historic hidden features), 22 (internal insulation, plastering, flooring or damp proofing measures) and 23 (match the original works) in relation to Listed Building Consent DMPA/2025/1043 at

Old Hall Farm, Twyford Road, Twyford, Barrow-on-Trent, Derby, DE73 7GA

Planning Decision MadeReference: DMOT/2025/1729South Derbyshire District Council

Last published check: 22 Oct 2026, 06:06. Check the council record for more recent changes.

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Received

    Published milestoneCouncil source
  2. Validated

    Published milestoneCouncil source
  3. Consultation starts

    Published milestoneCouncil source
  4. Consultation deadline

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source
  5. Determination deadline

    Past published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source

Application summary

Status
Planning Decision Made
Application type
Not published
Received
24 Dec 2025
Validated
24 Dec 2025
Determination deadline
18 Feb 2026
Local authority
South Derbyshire District Council

Application overview

The approval of details reserved by conditions 3 (precise specifications or samples of the walling and roofing materials), 4 (any new masonry (including mortar) or materials shall match the existing materials in colour and texture), 5 (samples or detailed specifications of all external materials), 6 (New materials required for rebuild or repair to the Listed Building shall match the existing adjacent in respect of dimensions, colour, texture, face bond, and pointing), 7 ( sample panel(s) of all new facing work shall be provided on site showing the proposed - types, sizes, colour, texture face-bond pointing mortar mix, joint thickness and finish profile), 8 (method and extent of repointing), 9, (second-hand/salvaged materials), 10 (roofing sample panel), 11 (details of the treatment of verges and eaves), 12 (ventilation), 13 (roof lights), 14 (roof lights), 15 (rainwater goods), 16 (masonry cleaning), 17 (details of mortar mix), 18 (re-pointing mortar), 19 (windows and doors), 20 (trickle vents), 21 (historic hidden features), 22 (internal insulation, plastering, flooring or damp proofing measures) and 23 (match the original works) in relation to Listed Building Consent DMPA/2025/1043 at

Proposal details

Reference
DMOT/2025/1729

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Application location

Old Hall Farm, Twyford Road, Twyford, Barrow-on-Trent, Derby, DE73 7GA

This record has no verified map location.

Documents 81 of 81

DocumentPublishedAction
16d. sample downpipePhoto13 Jan 2026View
8f. glass link between main house and cow shedPhoto13 Jan 2026View
INTERNAL LINING & EXTERNAL BRICKWORK FOR COW SHED REBUILDDocument13 Feb 2026View
Stick on glazing barPlans24 Dec 2025View
Cover LetterDocument12 Jan 2026View
12e. sample lime mortar for construction workPhoto13 Jan 2026View
Engineering Bricks for DPC annexe and garagePhoto13 Feb 2026View
0236-SIG-00-00-DR-A-0210_Proposed Sections-S3-P02Plans24 Dec 2025View
Cover letterDocument24 Dec 2025View
8e. glazed corridor east sidePhoto13 Jan 2026View
22a STEICO-IWI-Installation-InstructionsDocument13 Jan 2026View
Existing wallPhoto24 Dec 2025View
8a. wood claddingPhoto13 Jan 2026View
22h. Flooring methodology and insulationDocument13 Jan 2026View
9b IMG matched mortarPhoto13 Jan 2026View
20d external door to cow shedPhoto13 Jan 2026View
Existing wallPhoto24 Dec 2025View
9c. sample mortar for pointingPhoto13 Jan 2026View
Existing buildingPhoto24 Dec 2025View
12d. photo of mismatched ridge tilesPhoto13 Jan 2026View
STEICO IWI Installation InstructionsDocument24 Dec 2025View
22g damp proof V1Document13 Jan 2026View
11d. staffordshire Blue roof tilePhoto13 Jan 2026View
Window sectionPlans24 Dec 2025View
9a image of current pointingPhoto13 Jan 2026View
Cow shed doorPlans24 Dec 2025View
20c internal doorsPhoto13 Jan 2026View
11a Cow shed roof diagramPlans13 Jan 2026View
Technical data sheet REABILITA CAL AC FinoDocument24 Dec 2025View
STEICO Building Systems and Wood Fibre Insulation BrochureDocument24 Dec 2025View
Existing detailsPhoto24 Dec 2025View
Brochura ISOVIT LIME EN.Document24 Dec 2025View
Limecrete-Floor-SectionPlans13 Jan 2026View
17b eco brickmortar cleanerDocument13 Jan 2026View
Breeze block construction for annexePhoto13 Feb 2026View
Existing wallPhoto24 Dec 2025View
Existing buildingPhoto24 Dec 2025View
Existing buildingPhoto24 Dec 2025View
22e Wood-Fibre-Board-Internal-Isovit-Lime-Build-up (2)Document13 Jan 2026View
16c.sample aluminium gutteringPhoto13 Jan 2026View
12c NHL 5 data sheetDocument13 Jan 2026View
16b Marley Alutec half round gutteringDocument13 Jan 2026View
Existing wallPhoto24 Dec 2025View
Decision NoticeDecision25 Mar 2026View
Stick on glazing butt and hingePlans24 Dec 2025View
8d. timber for porch.Photo13 Jan 2026View
14b rooflight section drawingDrawing13 Jan 2026View
22c Brochura-ISOVIT-LIME-ENDocument13 Jan 2026View
Mortar MixPhoto24 Dec 2025View
Wood Fibre Board Internal Isovit Lime Build upDocument24 Dec 2025View
20a drawings windows and external doorsDrawing13 Jan 2026View
14a Velux Heritage conservation roof lightsDocument13 Jan 2026View
22b Technical-data-sheet_REABILITA-CAL-AC-FinoDocument13 Jan 2026View
6a. floor insulation detailsPlans19 Jan 2026View
11b Cow_Shed_Roof methodologyDocument13 Jan 2026View
Roof construction for new garage and annexPlans24 Dec 2025View
22d steico wood fibre boardsDocument13 Jan 2026View
20b windowPhoto13 Jan 2026View
STEICO Internal Wall Insulation IWI Section 1Document24 Dec 2025View
17a Brick taking down and cleaning strategyDocument13 Jan 2026View
18a NHL-3.5-Product-DataDocument13 Jan 2026View
0236-SIG-00-00-DR-A-0204_Proposed Ground Floor Plan-S3-P02Plans24 Dec 2025View
Application Form - Without Personal DataForm24 Dec 2025View
8c.PorchPhoto13 Jan 2026View
Officer ReportDecision25 Mar 2026View
STEICO Internal Wall Insulation IWI 1Document24 Dec 2025View
MortarPhoto24 Dec 2025View
0236-SIG-00-00-DR-A-0205_Proposed First_Roof Plans-S3-P02Plans24 Dec 2025View
Existing buildingPhoto24 Dec 2025View
FloorInstallation-GuideDocument13 Jan 2026View
Existing guttteringPhoto24 Dec 2025View
18b matched mortar for repointingPhoto13 Jan 2026View
8b.Wood fibre insulation boardPhoto13 Jan 2026View
17a (Amended) Brick taking down and cleaning strategyDocument27 Feb 2026View
Rooflight section drawingPlans24 Dec 2025View
11c Roof construction for new garage and annexPhoto13 Jan 2026View
Internal doorsDocument24 Dec 2025View
22f STEICO-Internal-Wall-Insulation-IWI-Section-1Document13 Jan 2026View
Further information - Facing materials and sample panelsDocument20 Mar 2026View
12a IMG cow shed roofPhoto13 Jan 2026View
16a Marley Alutec Product Data Sheet Tudor Circular DownpipeDocument13 Jan 2026View

Documents open on the council website. Browse council documents if a link has changed.

Decision & conditions

Planning Decision Made
Decision Notice Officer Report
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Related records could not be loaded.

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.