Council planning record

Submission of details of the external facing materials including manufacturer's specifications and photographs of a physical sample, pursuant to Condition 3; details of an enhanced sound insulation value DnT,w and L'nT,w of at least 10dB above the Building Regulations value, for the floor/ceiling/wall structures separating the commercial parts of No.236 King Street from the residential dwelling at 1A Ravenscourt Road, pursuant to Condition 12; details of a Ventilation Strategy Report to mitigate the impact of existing poor air quality for the self-contained dwellinghouse, pursuant to Condition 19; and details of the windows at first- floor level in the north and south elevations which shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3, and shall be non-opening and fixed shut up to a height of 1.7m above the finished floor level, pursuant to Condition 25 of planning permission reference: 2022/02116/FUL dated 4th December 202... read more

1A Ravenscourt Road, London, W6 0UH

Decided: REFUSEReference: 2025/02964/DETLondon Borough of Hammersmith & Fulham

Application timeline

Council milestones and published deadlines. A deadline passing does not confirm a decision.

  1. Received

    Published milestoneCouncil source
  2. Validated

    Published milestoneCouncil source
  3. Registered

    Published milestoneCouncil source
  4. Statutory expiry date

    Published deadline

    A published target or deadline. It does not confirm an outcome.

    Council source

Application summary

Status
Decided: REFUSE
Application type
Not published
Received
23 Oct 2025
Validated
24 Oct 2025
Determination deadline
18 Dec 2028
Local authority
London Borough of Hammersmith & Fulham

Application overview

Submission of details of the external facing materials including manufacturer's specifications and photographs of a physical sample, pursuant to Condition 3; details of an enhanced sound insulation value DnT,w and L'nT,w of at least 10dB above the Building Regulations value, for the floor/ceiling/wall structures separating the commercial parts of No.236 King Street from the residential dwelling at 1A Ravenscourt Road, pursuant to Condition 12; details of a Ventilation Strategy Report to mitigate the impact of existing poor air quality for the self-contained dwellinghouse, pursuant to Condition 19; and details of the windows at first- floor level in the north and south elevations which shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3, and shall be non-opening and fixed shut up to a height of 1.7m above the finished floor level, pursuant to Condition 25 of planning permission reference: 2022/02116/FUL dated 4th December 202... read more

Proposal details

Reference
2025/02964/DET
Ward
Ravenscourt
Agent
Mr Patrick Rogers / Alan Power Architects Ltd

Sign in to view all collected council fields and recorded changes.

Sign in to view collected details

Application location

1A Ravenscourt Road, London, W6 0UH

This record has no verified map location.

Documents 46 of 46

DocumentPublishedAction
APPLICATIONFORMREDACTEDCouncil documentNot publishedView
PLANNING STATEMENTCouncil documentNot publishedView
647 - 316 REV A MATERIALS BOARD COPYCouncil documentNot publishedView
647 - 306 REV F SECTION C-C COPYCouncil documentNot publishedView
647 - 307 REV F SECTION D-D COPYCouncil documentNot publishedView
647 - 309 REV D EAST ELEVATION COPYCouncil documentNot publishedView
647 - 310 REV E NORTH ELEVATIONCouncil documentNot publishedView
647 - 312 REV D SECTION H-H COPYCouncil documentNot publishedView
647 - 313 REV C SOUTH ELEVATION COPYCouncil documentNot publishedView
647 - 314 REV A WINDOW AND DOOR SCHEDULECouncil documentNot publishedView
647 - 317 REV A FEATURE WINDOW - FRONT ELEVATION COPYCouncil documentNot publishedView
647 - 318 REV A FEATURE WINDOW - SIDE ELEVATION COPYCouncil documentNot publishedView
647 - 319 REV A TYPICAL SLIDING DOOR DETAIL COPYCouncil documentNot publishedView
COR 70 HIDDEN SASH C16 STCouncil documentNot publishedView
COR VISION SLIDINGCouncil documentNot publishedView
IMPERIAL-BRICKS-WINDSOR-WEATHERED-YELLOW-MULTI-STOCK-DUAL-FACED-DATA-SHEETCouncil documentNot publishedView
STOCKHOLM BROWN GLAZEDCouncil documentNot publishedView
OPTIFLOATOPAL_ DATASHEETCouncil documentNot publishedView
ROOFING VMZINC-ROOFING-ON-VENTED-PLYWOOD-SPEC-JANUARY-24Council documentNot publishedView
SIKA EXTENSIVE GREEN ROOF TYPICAL DETAILSCouncil documentNot publishedView
SIKA GREEN ROOF GENERAL MAINTENANCE - MAINTENANCE OF SEDUM ROOF SYSTEMS 05.21Council documentNot publishedView
SIKA SPEC SIKA NATUREROOF EXTENSIVE SEDUM BLANKET WARM ROOFCouncil documentNot publishedView
SIKAPLAN_SGMA-20Council documentNot publishedView
SIKAROOF-SEDUM-BLANKET SPECIES UKCouncil documentNot publishedView
SIKAROOF-SUBSTRATEEXTENSIVEUKCouncil documentNot publishedView
VELUX - GGL_62_ELECTRIC_EXTRA_SOUND_REDUCTION_WALL_SWITCH_EN-GB_GB COPYCouncil documentNot publishedView
VELUX - SOLAR ROOF WINDOW GGL. PDFCouncil documentNot publishedView
VM ZINC DATA SHEET STANDING SEAM ON VENTED PLYWOODCouncil documentNot publishedView
VM ZINC TYPICAL DETAILSCouncil documentNot publishedView
BRITISH-GYPSUM-PDS-GYPROC-SOUNDBLOC-12-5MMCouncil documentNot publishedView
REDUCTOCLIP DIRECT TO WALL BROCHURECouncil documentNot publishedView
REDUCTOCLIP INDEPENDENT WALL BROCHURECouncil documentNot publishedView
REDUCTOCLIP SYSTEM CEILING PERFORMANCE DATA 2023-2ED00152Council documentNot publishedView
REDUCTOCLIP TIMBER JOIST CEILING SYSTEM BROCHURECouncil documentNot publishedView
REDUCTOCLIP_SYSTEM_WALL_PERFORMANCE_DATA_2023-DE8D0125Council documentNot publishedView
J3164 - VENTILATION STRATEGYCouncil documentNot publishedView
3164-57-0G-P2 GND FLOOR VENTILATION LAYOUTCouncil documentNot publishedView
3164-57-01-P2 1ST FLOOR VENTILATION LAYOUTCouncil documentNot publishedView
J3164_1A RAVENSCOURT ROAD_OVERHEATING ANALYSIS_1.0Council documentNot publishedView
PEA_PLOT 1_BE GREEN_2025-10-16Council documentNot publishedView
TITON-FIRESAFE-DOUBLE-AIR-BRICK-CATALOGUE-PAGEPDFCouncil documentNot publishedView
NUAIRE IAQBOX-DCouncil documentNot publishedView
NUAIRE_MRXBOX-ECO4- TECHNICALCouncil documentNot publishedView
647 - 251017 LBHF LETTERCouncil documentNot publishedView
DELEGATED OFFICER REPORTCouncil documentNot publishedView
REFUSAL OF DETAILS - FULL/OUTLINECouncil documentNot publishedView

Documents open on the council website. Browse council documents if a link has changed.

Decision & conditions

Decided: REFUSE
Planning conditions

Conditions aren’t listed here. Read the council decision notice for the full decision and conditions.

Related records

Understand this planning record

All planning guides
  • Understanding planning · 13 min read

    Planning application documents: what to read first

    Understand planning application documents, officer reports and decision notices. Use a reading checklist, document table and worked example to inspect a case.

  • Understanding planning · 13 min read

    Planning application statuses explained

    Understand pending consideration, approved, refused and withdrawn planning applications. Compare status labels and find the documents explaining each outcome.

  • Understanding planning · 13 min read

    Planning permission drawings: how to read plans

    Read planning drawings, floor plans, elevations and sections. Use labelled diagrams, a drawing comparison table and revision checks to understand a proposal.